{"id":2219,"date":"2023-09-28T09:08:41","date_gmt":"2023-09-28T07:08:41","guid":{"rendered":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/?p=2219"},"modified":"2023-11-24T11:46:57","modified_gmt":"2023-11-24T10:46:57","slug":"dtu-24-1-controle-du-conduit-existant","status":"publish","type":"post","link":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/","title":{"rendered":"DTU 24.1 &#8211; Les 4 \u00e9tapes de contr\u00f4le d&rsquo;un conduit de fum\u00e9e existant"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.<\/p>\n","protected":false},"author":4,"featured_media":2221,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"inline_featured_image":false},"categories":[12],"tags":[],"acf":{"temps_de_lecture":"02","introduction":"<p><span style=\"font-weight: 400;\">La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation afin d\u2019en \u00e9valuer leur \u00e9tat global et d\u00e9terminer leur aptitude \u00e0 \u00e9vacuer les fum\u00e9es en fonction de diff\u00e9rents param\u00e8tres. <\/span><\/p>\n","blocs":[{"acf_fc_layout":"contenu_texte","texte":"<p><span style=\"font-weight: 400;\">Ce diagnostic doit \u00eatre r\u00e9alis\u00e9 avant tout raccordement des appareils et se d\u00e9compose en quatre parties : <strong>l\u2019identification, la vacuit\u00e9, l\u2019\u00e9tanch\u00e9it\u00e9<\/strong> et une possible <strong>r\u00e9habilitation<\/strong> dans le cas de conduit non conforme au diagnostic.<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2><strong>Quand r\u00e9aliser un diagnostic ?<\/strong><\/h2>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Si le conduit existant est ant\u00e9rieur \u00e0 la norme NF DTU 24.1 de f\u00e9vrier 2006<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Si la d\u00e9signation d\u2019un conduit existant conforme \u00e0 la norme NF DTU 24.1, est adapt\u00e9e. Dans le cas contraire, il faut directement passer \u00e0 l\u2019\u00e9valuation de sa r\u00e9habilitation. <\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>Les bases<\/strong><\/h2>\n<p><img loading=\"lazy\" class=\"aligncenter wp-image-2220\" src=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-scaled.jpg\" alt=\"blog-reglementation-schema-base-controle-conduit\" width=\"442\" height=\"395\" srcset=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-scaled.jpg 2560w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-300x268.jpg 300w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-1024x916.jpg 1024w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-768x687.jpg 768w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-1536x1374.jpg 1536w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-schema-base-controle-conduit-2048x1833.jpg 2048w\" sizes=\"(max-width: 442px) 100vw, 442px\" \/><\/p>\n<p>&nbsp;<\/p>\n<h2><strong>1 &#8211; L\u2019identification<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Cette phase consiste \u00e0 <strong>rassembler le plus d\u2019informations possible sur le conduit<\/strong> : type, nature, hauteur, implantation, trac\u00e9, section, d\u00e9bouch\u00e9, etc\u2026.\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><strong>Effectuer un rep\u00e9rage et un tra\u00e7age<\/strong><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Rep\u00e9rer pour chaque conduit : l\u2019\u00e9tage ou le niveau desservi, ainsi que la souche ou le couronnement<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Pour des op\u00e9rations importantes de r\u00e9habilitation, il convient de tracer un plan de toiture avec les rep\u00e9rages not\u00e9s (num\u00e9ro des \u00e9tages desservis)\u00a0 ainsi qu\u2019une coupe sch\u00e9matique de l\u2019immeuble (avec croquis des cr\u00e9maill\u00e8res) en y reportant la longueur et diam\u00e8tre des conduits.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Dans le collectif, la rel\u00e8ve d\u2019informations est un peu plus pr\u00e9cise, voir <a href=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/solution-collectif\/dtu-24-1-controle-des-conduits-existants-dans-le-collectif\/\" target=\"_blank\" rel=\"noopener\">dans cet article<\/a>.<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>2 &#8211; La vacuit\u00e9<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Ce contr\u00f4le consiste \u00e0 <strong>v\u00e9rifier l\u2019int\u00e9rieur du conduit<\/strong>. Il peut \u00eatre r\u00e9alis\u00e9 de mani\u00e8re isol\u00e9e ou au m\u00eame moment que le ramonage, gr\u00e2ce \u00e0 un h\u00e9risson.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">\u00c0 noter que ce contr\u00f4le peut \u00eatre effectu\u00e9 \u00e0 l\u2019aide d\u2019un miroir pour les conduits sans d\u00e9voiement, ou \u00e9galement lors d\u2019une inspection vid\u00e9o (devant respecter les instructions du DTU 24.1, annexe C).\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<h2><strong>3 &#8211; L\u2019\u00e9tanch\u00e9it\u00e9<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">La phase d\u2019\u00e9tanch\u00e9it\u00e9 a pour <strong>objectif d\u2019\u00e9viter les risques d\u2019intoxication<\/strong> pour les occupants et de d\u00e9tecter toute potentielle fissure pouvant provoquer un dysfonctionnement du syst\u00e8me d\u2019\u00e9vacuation.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Les 2 m\u00e9thodes existent :\u00a0<\/span><\/p>\n<ul>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">L\u2019essai fumig\u00e8ne &#8211; consiste \u00e0 br\u00fbler un fumig\u00e8ne dans le conduit et rechercher les fuites \u00e9ventuelles de fum\u00e9e \u00e0 travers ce dernier. Au moins deux op\u00e9rateurs doivent \u00eatre pr\u00e9sents \u00e0 chaque extr\u00e9mit\u00e9 du conduit.\u00a0<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">La mesure de la perm\u00e9abilit\u00e9 de l\u2019air &#8211; permet de quantifier le taux de fuite dans les conduits \u00e0 v\u00e9rifier.\u00a0<\/span><\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2><strong>4 &#8211; L\u2019\u00e9valuation de la r\u00e9habilitation<\/strong><\/h2>\n<p><span style=\"font-weight: 400;\">Si un conduit n\u2019est pas conforme au diagnostic, il faut <strong>\u00e9valuer sa r\u00e9habilitation<\/strong> soit en chemisage, soit en <a href=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-tubage-dun-conduit-existant\/\" target=\"_blank\" rel=\"noopener\">tubage<\/a>.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Dans le cas d\u2019un conduit qui ne peut pas \u00eatre utilis\u00e9 ni r\u00e9habilit\u00e9, il faut envisager la construction d\u2019un conduit neuf et ce dernier doit \u00eatre totalement condamn\u00e9.\u00a0<\/span><\/p>\n<p>&nbsp;<\/p>\n<p><i><span style=\"font-weight: 400;\">Sources : DTU 24.2 P1.1, paragraphes 5.1.1 et 6.5; Guide pratique D\u00e9veloppement durable &#8211; Po\u00eales et inserts \u00e0 granul\u00e9s &#8211; CSTB Editions<\/span><\/i><\/p>\n<p>&nbsp;<\/p>\n<p>___________________________________________________________________________________________________________________________________________________________________________<\/p>\n<p>&nbsp;<\/p>\n<h3 style=\"text-align: center;\"><strong>Jeremias France, fournisseur de conduits de fum\u00e9e travaille au quotidien avec ses partenaires pour vous faire vivre une nouvelle exp\u00e9rience en fumisterie !<\/strong><\/h3>\n<p><a href=\"https:\/\/jeremias.fr\/product-finder\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" class=\"aligncenter wp-image-2186 \" src=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/cta-commande.png\" alt=\"Bouton acc\u00e8s commande\" width=\"583\" height=\"175\" srcset=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/cta-commande.png 1000w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/cta-commande-300x90.png 300w, https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/cta-commande-768x230.png 768w\" sizes=\"(max-width: 583px) 100vw, 583px\" \/><\/a><\/p>\n<p>___________________________________________________________________________________________________________________________________________________________________________<\/p>\n"}],"push_articles":[{"ID":2183,"post_author":"4","post_date":"2022-02-25 09:04:52","post_date_gmt":"2022-02-25 08:04:52","post_content":"","post_title":"DTU 24.2 - Quelles obligations pour l'amen\u00e9e d'air frais ?","post_excerpt":"Une alimentation d\u2019air frais suppl\u00e9mentaire est obligatoire pour le bon fonctionnement des appareils. Que dit le DTU sur cet apport ?","post_status":"publish","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"dtu-24-2-amenee-air-appareils","to_ping":"","pinged":"","post_modified":"2023-11-24 11:55:35","post_modified_gmt":"2023-11-24 10:55:35","post_content_filtered":"","post_parent":0,"guid":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/?p=2183","menu_order":0,"post_type":"post","post_mime_type":"","comment_count":"0","filter":"raw"},{"ID":1744,"post_author":"4","post_date":"2023-09-18 11:50:29","post_date_gmt":"2023-09-18 09:50:29","post_content":"","post_title":"DTU 24.1 - Les d\u00e9bouch\u00e9s en toiture et fa\u00e7ades des conduits pour appareils \u00e0 granul\u00e9s","post_excerpt":"La position du d\u00e9bouch\u00e9 du conduit doit \u00eatre conforme au DTU dans le but d\u2019\u00e9viter tout refoulement d\u00fb aux diff\u00e9rents impacts du vent sur la toiture.","post_status":"private","comment_status":"closed","ping_status":"closed","post_password":"","post_name":"lexpertise-du-mois-10-poeles-et-chaudieres-a-granules-les-debouches-de-conduits-en-facade","to_ping":"","pinged":"","post_modified":"2024-04-25 17:12:41","post_modified_gmt":"2024-04-25 15:12:41","post_content_filtered":"","post_parent":0,"guid":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/?p=1744","menu_order":0,"post_type":"post","post_mime_type":"","comment_count":"0","filter":"raw"}],"cta":"Lire plus","utiliser_layout_presta":true,"produits_suggeres":[]},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v19.2 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d&#039;un conduit de fum\u00e9e existant<\/title>\n<meta name=\"description\" content=\"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d&#039;un conduit de fum\u00e9e existant\" \/>\n<meta property=\"og:description\" content=\"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/\" \/>\n<meta property=\"og:site_name\" content=\"Jeremias\" \/>\n<meta property=\"article:published_time\" content=\"2023-09-28T07:08:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2023-11-24T10:46:57+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"542\" \/>\n\t<meta property=\"og:image:height\" content=\"355\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Eva Aristhene\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#website\",\"url\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/\",\"name\":\"Jeremias\",\"description\":\"Conduits de fum\u00e9e\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#primaryimage\",\"url\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg\",\"contentUrl\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg\",\"width\":542,\"height\":355},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#webpage\",\"url\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/\",\"name\":\"DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d'un conduit de fum\u00e9e existant\",\"isPartOf\":{\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#primaryimage\"},\"datePublished\":\"2023-09-28T07:08:41+00:00\",\"dateModified\":\"2023-11-24T10:46:57+00:00\",\"author\":{\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/2518c1fa4589388d2bab7ed32a876fbc\"},\"description\":\"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.\",\"breadcrumb\":{\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"DTU 24.1 &#8211; Les 4 \u00e9tapes de contr\u00f4le d&rsquo;un conduit de fum\u00e9e existant\"}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/2518c1fa4589388d2bab7ed32a876fbc\",\"name\":\"Eva Aristhene\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/e343496645205962ea96d224272593c0?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/e343496645205962ea96d224272593c0?s=96&d=mm&r=g\",\"caption\":\"Eva Aristhene\"},\"url\":\"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/author\/eva-aristhenejeremias-france-fr\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d'un conduit de fum\u00e9e existant","description":"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/","og_locale":"fr_FR","og_type":"article","og_title":"DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d'un conduit de fum\u00e9e existant","og_description":"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.","og_url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/","og_site_name":"Jeremias","article_published_time":"2023-09-28T07:08:41+00:00","article_modified_time":"2023-11-24T10:46:57+00:00","og_image":[{"width":542,"height":355,"url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg","type":"image\/jpeg"}],"author":"Eva Aristhene","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#website","url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/","name":"Jeremias","description":"Conduits de fum\u00e9e","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"fr-FR"},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#primaryimage","url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg","contentUrl":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/app\/uploads\/2022\/02\/blog-reglementation-image-dtu-controle-conduit.jpg","width":542,"height":355},{"@type":"WebPage","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#webpage","url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/","name":"DTU 24.1 - Les 4 \u00e9tapes de contr\u00f4le d'un conduit de fum\u00e9e existant","isPartOf":{"@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#website"},"primaryImageOfPage":{"@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#primaryimage"},"datePublished":"2023-09-28T07:08:41+00:00","dateModified":"2023-11-24T10:46:57+00:00","author":{"@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/2518c1fa4589388d2bab7ed32a876fbc"},"description":"La norme NF DTU 24.1 impose de r\u00e9aliser un diagnostic des conduits de fum\u00e9e avant utilisation ou r\u00e9utilisation.","breadcrumb":{"@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/reglementation\/dtu-24-1-controle-du-conduit-existant\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/"},{"@type":"ListItem","position":2,"name":"DTU 24.1 &#8211; Les 4 \u00e9tapes de contr\u00f4le d&rsquo;un conduit de fum\u00e9e existant"}]},{"@type":"Person","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/2518c1fa4589388d2bab7ed32a876fbc","name":"Eva Aristhene","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/e343496645205962ea96d224272593c0?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/e343496645205962ea96d224272593c0?s=96&d=mm&r=g","caption":"Eva Aristhene"},"url":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/la-revue\/author\/eva-aristhenejeremias-france-fr\/"}]}},"formatted_date":"28 septembre 2023","_links":{"self":[{"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/posts\/2219"}],"collection":[{"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/comments?post=2219"}],"version-history":[{"count":5,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/posts\/2219\/revisions"}],"predecessor-version":[{"id":2907,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/posts\/2219\/revisions\/2907"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/media\/2221"}],"wp:attachment":[{"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/media?parent=2219"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/categories?post=2219"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/jeremias.fr\/fabricant-conduit-tubage\/wp-json\/wp\/v2\/tags?post=2219"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}